Specification
Type |
Pole |
Rated current (A) |
Rated insulation voltage (V) |
Rated operation voltage (V) |
Arcing-over Distance (mm) |
Ultimate short-circuit Breaking capacity (KA) |
Service short-circuit Breaking capacity (KA) |
Operation performance |
Utilization category |
JM1-63L |
3P/4P |
6,10,16,20,25 32,40,50,63 |
660 |
380 |
0 |
25 |
18 |
1500 |
8500 |
JM1-63M |
660 |
380 |
0 |
50 |
35 |
1500 |
8500 |
||
JM1-100L |
3P/4P |
10,16,20,25,32, |
660 |
380 |
0 |
35 |
22 |
1500 |
8500 |
JM1-100M |
660 |
380 |
≤50 |
50 |
35 |
1500 |
8500 |
||
JM1-100H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-225L |
3P/4P |
100, 125, 160, 180, 200, 225 |
660 |
380 |
≤50 |
35 |
22 |
1000 |
7000 |
JM1-225M |
660 |
380 |
≤50 |
50 |
35 |
1000 |
7000 |
||
JM1-225H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-400L |
3P/4P |
225, 250, 315, 350, 400 |
660 |
380 |
≤50 |
50 |
35 |
1000 |
4000 |
JM1-400M |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-400H |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-630L |
3P |
400, 500, 630 |
660 |
380 |
≤100 |
50 |
35 |
1000 |
4000 |
JM1-630M |
660 |
380 |
≤100 |
65 |
42 |
1000 |
4000 |
||
JM1-630H |
660 |
380 |
≤100 |
65 |
65 |
1000 |
4000 |
||
JM1-800M |
3P |
630, 700, 800 |
660 |
380 |
≤100 |
75 |
50 |
1000 |
4000 |
JM1-800H |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
||
JM1-1250M |
3P |
1000, 1250 |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
JM1-1250H |
660 |
380 |
≤100 |
125 |
75 |
1000 |
4000 |
||
JM1-1600M |
3P |
1600 |
660 |
380 |
≤100 |
150 |
80 |
1000 |
4000 |
Note
1.The MCCB has L; M; H types according to their rated limit short-circuit breaking capacity.
2.The MCCB is advantageous for its compact body, high breaking capacity(some even on flying arc), short arc-casting.
3.The MCCB has function of insulation wit its mark
4.The product complies with IEC60947-2, GB14048.2. Type code & signification
5.N-P type from 4-P has 3 types: A type: N-P without current tripper(normally open);
6.B type: N-P without current tripper working together with other 3P;
7.C type: N-P without current tripper working together with other 3P;
8.No code for distribution type breakers, 2 for motor-protection type;
9.No-code for distribution type breakers, 2 for motor-protection type;
It can be divided into L (common) type, M (standard) type and H (high) type. L type with connecting current equal to relevant frame level and M type with breaking capacity equaling to their frame level according to their rated limited short short-circuit breaking capacity (l c u).
10.Normal working situation
11.Altitude 2000m and below;
12.Ambient temperature no higher than+40ºC(45ºC for watercraft)no less than-5ºC;
13.Stand moist air;
14.Stand salty&oil mildew;
15.Most gradient 22.5°;
16.Atmosphere without corrupt&electric air and no danger of explosion;
17.Without rain effect.
Product detail pictures:















Related Product Guide:
We usually think and practice corresponding for the change of circumstance, and grow up. We aim at the achievement of a richer mind and body as well as the living for OEM/ODM Manufacturer Magnetic Starter - Moulded Case Circuit Breaker JM1 – JUHONG , The product will supply to all over the world, such as: Florence, Wellington, Bangladesh, Corporate goal: Customers' satisfaction is our goal, and sincerely hope to establish long-terms stable cooperative relations with customers to jointly develop the market. Building brilliant tomorrow together!Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.

The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!