OEM Customized Motor Starter Protector - GV2-M motor protector with overcurrent protection – JUHONG

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

The incredibly rich projects administration experiences and a person to 1 service model make the substantial importance of organization communication and our easy understanding of your expectations for Compact Circuit Breaker, Ls Mccb, Motor Starter Protector, We welcome clients, enterprise associations and friends from all components from the earth to make contact with us and find cooperation for mutual positive aspects.
OEM Customized Motor Starter Protector - GV2-M motor protector with overcurrent protection – JUHONG Detail:

Technical Characteristic

Type Rated current of trip unit In(A) Setting current adjustment range (A) Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) Arcing distance (mm)
230/240V 400/415V 440V 500V 690V
Icu Ics Icu Ics

Icu

Ics Icu Ics Icu Ics
0.16

0.1-0.16

100 100 100 100

100

100 100 100 100 100

40

0.25

0.16-0.25

100 100 100 100

100

100 100 100 100 100

40

JGV2-32 0.4

0.25-0.4

100 100 100 100

100

100 100 100 100 100

40

0.63

0.4-0.63

100 100 100 100

100

100 100 100 100 100

40

1 0.63-1 100 100 100 100

100

100 100 100 100 100

40

1.6 1-1.6 100 100 100 100

100

100 100 100 100 100

40

2.5 1.6-2.5 100 100 100 100

100

100 100 100 3 2.25

40

4 2.5-4 100 100 100 100

100

100 100 100 3 2.25

40

6.3 4-6.3 100 100 100 100

50

50 50 50 3 2.25

40

10 6-10 100 100 100 100

15

15 10 10 3 2.25

40

14 9-14 100 100 15 7.5

8

4 6 4.5 3 2.25

40

18 13-18 100 100 15 7.5

8

4 6 4.5 3 2.25

40

23 17-23 50 50 15 6

6

3 4 3 3 2.25

40

32 24-32 50 50 15 6

6

3 4 3 3 2.25

40

JGV3-80 40 25-40 - - 35 17.5 - - - - 4 2

50

63 40-63 - - 35 17.5 - - - - 4 2

50

80 56-80 - - 35 17.5 - - - - 4 2

50

 

Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)

Type Rated current of trip unit In(A) Rated current adjustment range (A) Standard rated power of three-phase motor (kW)
AC-3, 50Hz/60Hz
230/240V

400V

415V

440V

500V

690V
0.06 0.1-0.16 - - - - - -
0.25 0.6-0.25 - - - - - -
JGV2-32 0.4 0.25-0.4 - - - - - -
0.63 0.4-0.63 - - - - - 0.37
1 0.63-1 - - -

0.37

0.37

0.55
1.6 1-1.6 -

0.37

-

0.55

0.75

1.1
2.5 1.6-2.5 0.37

0.75

0.75

1.1

1.1

1.5
4 2.5-4 0.75

1.5

1.5

1.5

2.2

3
6.3 4-6.3 1.1

2.2

2.2 3

3.7

4
10 6-10 2.2 4 4 4

5.5

7.5
14 9-14 3

5.5

5.5

7.5

7.5

9
18 13-18 4

7.5

9 9 9 11
23 17-23 5.5 11 11

11

11 15
32 24-32 7.5 15 15

15

18.5

26
JGV3-80 40 25-40 -

18.5

- - - 30
63 40-63 -

30

- - - 45
80 56-80 - 37 - - - 55

 

The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)

Type Frame rated current Inm(A) Operating cycles per hour Operation cycle times
Power ups No power Total
1 32 120 2000 10000 12000
2 80 120 2000 10000 12000

Outline and Mounting Dimension

product5


Product detail pictures:


Related Product Guide:

Adhering into the theory of "quality, services, efficiency and growth", now we have gained trusts and praises from domestic and international shopper for OEM Customized Motor Starter Protector - GV2-M motor protector with overcurrent protection – JUHONG , The product will supply to all over the world, such as: Estonia, Latvia, Belize, "Good quality and reasonable price" are our business principles. If you are interested in our products or have any questions, make sure you feel free to contact us. We hope to establish cooperative relationships with you in the near future.
Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
5 Stars By Victor Yanushkevich from Afghanistan - 2018.07.26 16:51
The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
5 Stars By Adelaide from Brazil - 2018.12.10 19:03
Write your message here and send it to us