NSX250N MCCB 160-250A
JNSX-250 |
||||||||||
Number of poles |
3P□4P |
|||||||||
Shell frame maximum |
rated current Inm(A) |
|
|
|
250 |
|
|
|||
Rated current In(A) |
TM MA |
100/160/180/200/225/250 |
||||||||
|
|
250 |
|
|||||||
Rated insulation voltage Ui(V) |
|
|
|
|
1000 |
|
|
|||
Rated impulse withstand voltage Ulimp(kV) |
|
|
|
|
8 |
|
|
|||
50H-60Hz Rated voltage Ue(V) 50H-60Hz |
|
|
A |
400/4 |
415/500/690 |
690 |
|
|||
Flying arc Distance(mim) |
|
|
|
|
|
|
|
|||
Short circuit breaking capability level |
N |
|
- |
|
M |
H |
S |
|||
AC400/415V |
35 |
|
50 |
|
85 |
100 |
150 |
|||
Rated limit Short circuit |
/ |
|
35 |
|
50 |
60 |
65 |
|||
|
AC690V |
/ |
|
|
6 |
|
8 |
10 |
||
Usage Category |
|
|
|
|
|
A |
|
|
||
|
AC400/415V |
35 |
50 |
|
|
85 |
100 |
150 |
||
Rated running shortcircuit |
/ |
|
35 |
|
50 |
60 |
65 |
|||
AC690V |
/ |
|
|
6 |
|
8 |
10 |
|||
Rated short time resistant |
Type of Stripper |
|
|
|
3(micr |
logic 5.0A |
|
|
||
Additional Residual cu |
rent protection module(See P12-13 EL6 remaining current |
|||||||||
Electrical Life Test |
AC415V |
|
|
|
|
8000 |
|
|
|
|
AC690V |
|
|
|
|
1500 |
|
|
|
||
Number of mechanical life |
|
|
|
|
2 |
0000 |
|
|
|
|
|
|
|||||||||
Type |
JNSX-400 |
|
|
JNSX-630 |
JNSX- |
250/1600 |
||||
Number of poles |
3P,4P |
|
|
3P,4P |
|
月 |
IP,4P |
|||
Shell frame maximum rated current Inm(A) |
400 |
|
|
630 |
|
125 |
0/1600 |
|||
TM MA |
250/315//350/400 |
|
|
400/500//600 |
|
|
/ |
|||
|
Electronic type |
400 |
|
|
630 |
|
630/800/1 |
000/1250/1600 |
||
Rated insulation voltage Ui(V) |
1000 |
|
|
1000 |
|
|
:1000 |
|||
Rated impulse withstand voltage Ump(kV) |
8 |
|
|
8 |
|
|
8 |
|||
50H-60Hz Rated voltage Ue(V)50H-60Hz |
AC400/415/500/690V |
|
|
AC400/415/500/690V |
|
AC400/ |
415/500/690V |
|||
Flying arc Distance(mm) |
|
|
|
0 |
|
|
|
|
||
Short circuit breaking capability level |
||||||||||
Rated limit Short circuit |
AC400/415V |
85 100 |
150 50 |
85 |
100 |
|||||
Breaking |
AC500V |
50 60 |
65 35 |
50 |
60 |
35 |
||||
|
AC690V |
10 |
20 |
10 |
15 20 |
20 |
||||
Rated running |
AC400/415V |
85 100 |
150 |
50 |
85 |
100 150 |
50 |
|||
Breaking |
AC500V |
50 |
65 |
35 |
50 |
60 65 |
35 45 |
|||
capacityics(kA) |
AC690V |
10 15 |
20 |
|
10 |
15 20 |
20 30 |
|||
Working with |
|
TM/MA micrologic 2 |
A |
|
|
|
A |
/ |
||
|
|
micrologic 5.0A |
B |
|
|
11 |
|
B |
||
Rated short time resistant current ICW(kA)(1s) |
||||||||||
Remaining Current |
protection |
onal Residual current |
pro |
ction |
tule(Se |
P12-13 |
L6 remain |
aining current |
module for |
|
Electrical Life Test |
AC415V |
6000 |
|
|
|
5000 |
|
1500 |
|
|
|
AC690V |
1000 |
|
|
|
1000 |
|
1000 |