High Quality for Mccb Merlin Gerin - Motor Protector With Overload Protection JGV2 – JUHONG

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our enterprise since its inception, constantly regards product good quality as organization life, constantly improve production technology, strengthen merchandise high quality and continuously strengthen enterprise total good quality administration, in strict accordance with all the national standard ISO 9001:2000 for 12v Contactor Relay, Ac Contactor Cj20, Magnetic Latching Contactor, We sincerely welcome both foreign and domestic business partners, and hope to work with you in the near future!
High Quality for Mccb Merlin Gerin - Motor Protector With Overload Protection JGV2 – JUHONG Detail:

Technical Characteristic

Type Rated current of trip unit In(A) Setting current adjustment range (A) Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) Arcing distance (mm)
230/240V 400/415V 440V 500V 690V
Icu Ics Icu Ics

Icu

Ics Icu Ics Icu Ics
0.16

0.1-0.16

100 100 100 100

100

100 100 100 100 100

40

0.25

0.16-0.25

100 100 100 100

100

100 100 100 100 100

40

JGV2-32 0.4

0.25-0.4

100 100 100 100

100

100 100 100 100 100

40

0.63

0.4-0.63

100 100 100 100

100

100 100 100 100 100

40

1 0.63-1 100 100 100 100

100

100 100 100 100 100

40

1.6 1-1.6 100 100 100 100

100

100 100 100 100 100

40

2.5 1.6-2.5 100 100 100 100

100

100 100 100 3 2.25

40

4 2.5-4 100 100 100 100

100

100 100 100 3 2.25

40

6.3 4-6.3 100 100 100 100

50

50 50 50 3 2.25

40

10 6-10 100 100 100 100

15

15 10 10 3 2.25

40

14 9-14 100 100 15 7.5

8

4 6 4.5 3 2.25

40

18 13-18 100 100 15 7.5

8

4 6 4.5 3 2.25

40

23 17-23 50 50 15 6

6

3 4 3 3 2.25

40

32 24-32 50 50 15 6

6

3 4 3 3 2.25

40

JGV3-80 40 25-40 - - 35 17.5 - - - - 4 2

50

63 40-63 - - 35 17.5 - - - - 4 2

50

80 56-80 - - 35 17.5 - - - - 4 2

50

 

Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)

The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)

Type Frame rated current Inm(A) Operating cycles per hour Operation cycle times
Power ups No power Total
1 32 120 2000 10000 12000
2 80 120 2000 10000 12000

Outline and Mounting Dimension

product5


Product detail pictures:


Related Product Guide:

We keep on with our business spirit of "Quality, Performance, Innovation and Integrity". We goal to create much more worth for our customers with our rich resources, state-of-the-art machinery, experienced workers and exceptional providers for High Quality for Mccb Merlin Gerin - Motor Protector With Overload Protection JGV2 – JUHONG , The product will supply to all over the world, such as: Brunei, Hamburg, Albania, We pay high attention to customer service, and cherish every customer. We have maintained a strong reputation in the industry for many years. We are honest and work on building a long-term relationship with our customers.
The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
5 Stars By Martina from Comoros - 2018.11.04 10:32
This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
5 Stars By Chris from Wellington - 2018.02.08 16:45
Write your message here and send it to us