Specification
|
Type |
Pole |
Rated current (A) |
Rated insulation voltage (V) |
Rated operation voltage (V) |
Arcing-over Distance (mm) |
Ultimate short-circuit Breaking capacity (KA) |
Service short-circuit Breaking capacity (KA) |
Operation performance |
Utilization category |
| JM1-63L |
3P/4P |
6,10,16,20,25 32,40,50,63 |
660 |
380 |
0 |
25 |
18 |
1500 |
8500 |
| JM1-63M |
660 |
380 |
0 |
50 |
35 |
1500 |
8500 |
||
| JM1-100L |
3P/4P |
10,16,20,25,32, |
660 |
380 |
0 |
35 |
22 |
1500 |
8500 |
| JM1-100M |
660 |
380 |
≤50 |
50 |
35 |
1500 |
8500 |
||
| JM1-100H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
| JM1-225L |
3P/4P |
100, 125, 160, 180, 200, 225 |
660 |
380 |
≤50 |
35 |
22 |
1000 |
7000 |
| JM1-225M |
660 |
380 |
≤50 |
50 |
35 |
1000 |
7000 |
||
| JM1-225H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
| JM1-400L |
3P/4P |
225, 250, 315, 350, 400 |
660 |
380 |
≤50 |
50 |
35 |
1000 |
4000 |
| JM1-400M |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
| JM1-400H |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
| JM1-630L |
3P |
400, 500, 630 |
660 |
380 |
≤100 |
50 |
35 |
1000 |
4000 |
| JM1-630M |
660 |
380 |
≤100 |
65 |
42 |
1000 |
4000 |
||
| JM1-630H |
660 |
380 |
≤100 |
65 |
65 |
1000 |
4000 |
||
| JM1-800M |
3P |
630, 700, 800 |
660 |
380 |
≤100 |
75 |
50 |
1000 |
4000 |
| JM1-800H |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
||
| JM1-1250M |
3P |
1000, 1250 |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
| JM1-1250H |
660 |
380 |
≤100 |
125 |
75 |
1000 |
4000 |
||
| JM1-1600M |
3P |
1600 |
660 |
380 |
≤100 |
150 |
80 |
1000 |
4000 |
Note
1.The MCCB has L; M; H types according to their rated limit short-circuit breaking capacity.
2.The MCCB is advantageous for its compact body, high breaking capacity(some even on flying arc), short arc-casting.
3.The MCCB has function of insulation wit its mark
4.The product complies with IEC60947-2, GB14048.2. Type code & signification
5.N-P type from 4-P has 3 types: A type: N-P without current tripper(normally open);
6.B type: N-P without current tripper working together with other 3P;
7.C type: N-P without current tripper working together with other 3P;
8.No code for distribution type breakers, 2 for motor-protection type;
9.No-code for distribution type breakers, 2 for motor-protection type;
It can be divided into L (common) type, M (standard) type and H (high) type. L type with connecting current equal to relevant frame level and M type with breaking capacity equaling to their frame level according to their rated limited short short-circuit breaking capacity (l c u).
10.Normal working situation
11.Altitude 2000m and below;
12.Ambient temperature no higher than+40ºC(45ºC for watercraft)no less than-5ºC;
13.Stand moist air;
14.Stand salty&oil mildew;
15.Most gradient 22.5°;
16.Atmosphere without corrupt&electric air and no danger of explosion;
17.Without rain effect.
Product detail pictures:
Related Product Guide:
we can easily offer you high-quality products and solutions, competitive rate and very best shopper support. Our destination is "You come here with difficulty and we give you a smile to take away" for Wholesale Dealers of Automatic Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG , The product will supply to all over the world, such as: Maldives, Netherlands, Lisbon, At Present, our products have been exported to more than sixty countries and different regions, such as Southeast Asia, America, Africa, Eastern Europe, Russia, Canada etc. We sincerely hope to establish wide contact with all potential customers both in China and the rest part of the world.
By Grace from panama - 2018.09.23 17:37
In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
By Stephen from Spain - 2018.12.22 12:52