Manufactur standard Compressor Motor Protector - GV2-M motor protector with overcurrent protection – JUHONG
Manufactur standard Compressor Motor Protector - GV2-M motor protector with overcurrent protection – JUHONG Detail:
Technical Characteristic
| Type | Rated current of trip unit In(A) | Setting current adjustment range (A) | Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) | Arcing distance (mm) | |||||||||
| 230/240V | 400/415V | 440V | 500V | 690V | |||||||||
| Icu | Ics | Icu | Ics |
Icu |
Ics | Icu | Ics | Icu | Ics | ||||
| 0.16 |
0.1-0.16 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
| 0.25 |
0.16-0.25 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
| JGV2-32 | 0.4 |
0.25-0.4 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
| 0.63 |
0.4-0.63 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
| 1 | 0.63-1 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
| 1.6 | 1-1.6 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
| 2.5 | 1.6-2.5 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 3 | 2.25 |
40 |
|
| 4 | 2.5-4 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 3 | 2.25 |
40 |
|
| 6.3 | 4-6.3 | 100 | 100 | 100 | 100 |
50 |
50 | 50 | 50 | 3 | 2.25 |
40 |
|
| 10 | 6-10 | 100 | 100 | 100 | 100 |
15 |
15 | 10 | 10 | 3 | 2.25 |
40 |
|
| 14 | 9-14 | 100 | 100 | 15 | 7.5 |
8 |
4 | 6 | 4.5 | 3 | 2.25 |
40 |
|
| 18 | 13-18 | 100 | 100 | 15 | 7.5 |
8 |
4 | 6 | 4.5 | 3 | 2.25 |
40 |
|
| 23 | 17-23 | 50 | 50 | 15 | 6 |
6 |
3 | 4 | 3 | 3 | 2.25 |
40 |
|
| 32 | 24-32 | 50 | 50 | 15 | 6 |
6 |
3 | 4 | 3 | 3 | 2.25 |
40 |
|
| JGV3-80 | 40 | 25-40 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 |
50 |
| 63 | 40-63 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 |
50 |
|
| 80 | 56-80 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 |
50 |
|
Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)
| Type | Rated current of trip unit In(A) | Rated current adjustment range (A) | Standard rated power of three-phase motor (kW) | |||||
| AC-3, 50Hz/60Hz | ||||||||
| 230/240V |
400V |
415V |
440V |
500V |
690V | |||
| 0.06 | 0.1-0.16 | - | - | - | - | - | - | |
| 0.25 | 0.6-0.25 | - | - | - | - | - | - | |
| JGV2-32 | 0.4 | 0.25-0.4 | - | - | - | - | - | - |
| 0.63 | 0.4-0.63 | - | - | - | - | - | 0.37 | |
| 1 | 0.63-1 | - | - | - |
0.37 |
0.37 |
0.55 | |
| 1.6 | 1-1.6 | - |
0.37 |
- |
0.55 |
0.75 |
1.1 | |
| 2.5 | 1.6-2.5 | 0.37 |
0.75 |
0.75 |
1.1 |
1.1 |
1.5 | |
| 4 | 2.5-4 | 0.75 |
1.5 |
1.5 |
1.5 |
2.2 |
3 | |
| 6.3 | 4-6.3 | 1.1 |
2.2 |
2.2 | 3 |
3.7 |
4 | |
| 10 | 6-10 | 2.2 | 4 | 4 | 4 |
5.5 |
7.5 | |
| 14 | 9-14 | 3 |
5.5 |
5.5 |
7.5 |
7.5 |
9 | |
| 18 | 13-18 | 4 |
7.5 |
9 | 9 | 9 | 11 | |
| 23 | 17-23 | 5.5 | 11 | 11 |
11 |
11 | 15 | |
| 32 | 24-32 | 7.5 | 15 | 15 |
15 |
18.5 |
26 | |
| JGV3-80 | 40 | 25-40 | - |
18.5 |
- | - | - | 30 |
| 63 | 40-63 | - |
30 |
- | - | - | 45 | |
| 80 | 56-80 | - | 37 | - | - | - | 55 | |
The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)
| Type | Frame rated current Inm(A) | Operating cycles per hour | Operation cycle times | ||
| Power ups | No power | Total | |||
| 1 | 32 | 120 | 2000 | 10000 | 12000 |
| 2 | 80 | 120 | 2000 | 10000 | 12000 |
Outline and Mounting Dimension

Product detail pictures:
Related Product Guide:
Good quality To start with,and Purchaser Supreme is our guideline to offer the top service to our customers.Presently, we've been seeking our best to be amongst the top exporters inside our industry to fulfill consumers extra need to have for Manufactur standard Compressor Motor Protector - GV2-M motor protector with overcurrent protection – JUHONG , The product will supply to all over the world, such as: London, Sydney, Sudan, If you need any of our products, or have other items to be produced, please send us your inquiries, samples or detailed drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.
By David from Sydney - 2017.01.11 17:15
It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
By Kevin Ellyson from Houston - 2017.12.02 14:11
Write your message here and send it to us