Factory Supply Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG
Factory Supply Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG Detail:
Specification
|
Type |
Pole |
Rated current (A) |
Rated insulation voltage (V) |
Rated operation voltage (V) |
Arcing-over Distance (mm) |
Ultimate short-circuit Breaking capacity (KA) |
Service short-circuit Breaking capacity (KA) |
Operation performance |
Utilization category |
| JM1-63L |
3P/4P |
6,10,16,20,25 32,40,50,63 |
660 |
380 |
0 |
25 |
18 |
1500 |
8500 |
| JM1-63M |
660 |
380 |
0 |
50 |
35 |
1500 |
8500 |
||
| JM1-100L |
3P/4P |
10,16,20,25,32, |
660 |
380 |
0 |
35 |
22 |
1500 |
8500 |
| JM1-100M |
660 |
380 |
≤50 |
50 |
35 |
1500 |
8500 |
||
| JM1-100H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
| JM1-225L |
3P/4P |
100, 125, 160, 180, 200, 225 |
660 |
380 |
≤50 |
35 |
22 |
1000 |
7000 |
| JM1-225M |
660 |
380 |
≤50 |
50 |
35 |
1000 |
7000 |
||
| JM1-225H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
| JM1-400L |
3P/4P |
225, 250, 315, 350, 400 |
660 |
380 |
≤50 |
50 |
35 |
1000 |
4000 |
| JM1-400M |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
| JM1-400H |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
| JM1-630L |
3P |
400, 500, 630 |
660 |
380 |
≤100 |
50 |
35 |
1000 |
4000 |
| JM1-630M |
660 |
380 |
≤100 |
65 |
42 |
1000 |
4000 |
||
| JM1-630H |
660 |
380 |
≤100 |
65 |
65 |
1000 |
4000 |
||
| JM1-800M |
3P |
630, 700, 800 |
660 |
380 |
≤100 |
75 |
50 |
1000 |
4000 |
| JM1-800H |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
||
| JM1-1250M |
3P |
1000, 1250 |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
| JM1-1250H |
660 |
380 |
≤100 |
125 |
75 |
1000 |
4000 |
||
| JM1-1600M |
3P |
1600 |
660 |
380 |
≤100 |
150 |
80 |
1000 |
4000 |
Note
1.The MCCB has L; M; H types according to their rated limit short-circuit breaking capacity.
2.The MCCB is advantageous for its compact body, high breaking capacity(some even on flying arc), short arc-casting.
3.The MCCB has function of insulation wit its mark
4.The product complies with IEC60947-2, GB14048.2. Type code & signification
5.N-P type from 4-P has 3 types: A type: N-P without current tripper(normally open);
6.B type: N-P without current tripper working together with other 3P;
7.C type: N-P without current tripper working together with other 3P;
8.No code for distribution type breakers, 2 for motor-protection type;
9.No-code for distribution type breakers, 2 for motor-protection type;
It can be divided into L (common) type, M (standard) type and H (high) type. L type with connecting current equal to relevant frame level and M type with breaking capacity equaling to their frame level according to their rated limited short short-circuit breaking capacity (l c u).
10.Normal working situation
11.Altitude 2000m and below;
12.Ambient temperature no higher than+40ºC(45ºC for watercraft)no less than-5ºC;
13.Stand moist air;
14.Stand salty&oil mildew;
15.Most gradient 22.5°;
16.Atmosphere without corrupt&electric air and no danger of explosion;
17.Without rain effect.
Product detail pictures:
Related Product Guide:
Our company insists all along the quality policy of "product good quality is base of enterprise survival; buyer fulfillment will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff" and also the consistent purpose of "reputation very first, shopper first" for Factory Supply Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG , The product will supply to all over the world, such as: Honduras, Moldova, Rome, With a wide range, good quality, reasonable prices and stylish designs, our solutions are extensively used in beauty and other industries. Our solutions are widely recognized and trusted by users and can meet continuously changing economic and social needs.
By Honorio from Provence - 2017.11.12 12:31
This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
By Christian from Honduras - 2018.10.01 14:14